Static Pressure Sensor for High Temperature Applications

The AutoPSI-DC is designed for static and dynamic pressure measurements in harsh environments characterized by high temperature up to 300°C, high levels of Electromagnetic and Radio Frequency Interference fields (EMI/RFI), and chemically volatile media.

The sensor targets the following applications:

  • The plastic industry, specifically in the monitoring of injection molding and extrusion

  • Monitoring and control of compressor pressure in natural gas pumping stations

  • Die-casting, turbine engines, oil exploration
  • Housed in a robust and low-cost package, the AutoPSI-DC signal conditioner is contained in a metal cylinder 1.5” (~3.8cm) in diameter and 4” (~10cm) long, permanently connected to a 6.5’ (~2m) long and high-temperature (200°C) cable. The sensor is powered by a DC source and provides pressure output of 0-5V, 0.5-5V, or 0-10V.

    The AutoPSI-DC sensor is available in a sealed gauge pressure package, with a non-corrosive and non-abrasive metal diaphragm. It is available in all standard Optrand sensor packages, with non-linearity & hysteresis of ±1% or ±0.5% and a frequency range of 0Hz to 15kHz. The sensor is also available in custom packages.

    Pressure Ranges 0-7 bar (~100 psi)
    0-14 bar (~200 psi)
    0-70 bar (~1,000 psi)
    0-100 bar (~1,500 psi)
    0-200 bar (~3,000 psi)
    0-700 bar (~10,000 psi)
    0-2,000 bar (~30,000 psi)
    Non-Linerarity & Hysteresis ± .5%, 1% FSO
    Output Signal Analog, 0.5 V to 5V
    0V to 5V
    0V to 10V
    Thermal Sensitivity Shift 0-200°C:±.5% FS
    200°C-360°C:۫% FS
    Diaphragm Resonant Frequency >120 kHz
    Frequency Range 0 Hz to 15 kHz
    Fiber-Optic Cable Length 2m (6.5') Standard
    Cable Minimum Bending Radius 20mm (~3/4")
    Sensor Housing Temp. Range -40 to 300°C (572°F)
    Cable Operating Temp. Range -20 to 200°C (392°F)
    Signal Conditioner temp. Range -20 to 65°C (146°F)
    Sensor Operational Mode Sealed Gauge
    Pressure Media Gaseous Liquid